l Technical Information Sheet RJ45-HUB

UNSCREENED TWISTED PAIR (UTP) TRANSIENT PROTECTION FOR HUBS

DATAPRO

  • Introduction

LAN network cabling is highly susceptible to induced transient overvoltages caused by lightning strikes and other voltage disturbances. These transients may be directly induced in the cabling or may be caused by differential earth voltages due to mains voltage disturbances.The Novaris RJ45-8CAT5 and RJ45-16CAT5 patch panel protectors are specially designed for the protection of twisted pair Ethernet systems and are compatible with category 5 cabling systems.

  • Operation

The RJ45-8CAT5 and RJ45-16CAT5 are patch panel protectors comprising two rows of RJ45 connectors in a 2 HU rack panel. Protection is provided by a custom array comprising high speed steering diodes and transil diodes connected from each line to line and to a common point for every line in every RJ45 connector. This common point connects to frame ground via an earthing link. The custom array presents extremely low shunt impedance to normal signals with low capacitance and hence minimal crosstalk. The result is a clamping voltage of 10V for transient overvoltages on every line of every RJ45 connector. The protector is suitable for category 5 cabling systems. Its effect on end to end performance is equivalent to approximately one meter of category 5 UTP cable. The protector may be used on all common UTP systems, using 10BaseT Ethernet and other signaling protocols.

  • Installation

Install the rack panel close to the hub to be protected. Patch from the hub to the protector using the patch cords provided. These are 250mm long. Replace the patch cords removed from the hub ports in the protector ports. It does not matter which is configured as line and load. Connect the protective earth wire to the equipment frame or the frame ground of the hub to be protected. Failure to do this will render the protection inoperable. It is also essential to consider protection for the power supply to the hub and other server components. Novaris Technologies power surge filters of an appropriate rating are suitable.

Specifications

  • Description: Shunt diode overvoltage protector for UTP cabling incorporating RJ45 connectors.

  • Lines protected: 8 lines of 8 ports or 16 ports

  • Protection modes: Transverse and common mode

  • Protection stages: High speed transil diodes.

  • Clamping voltage: 10V line to line, transverse

  • 10V line to frame, common

  • Surge withstand: 40A 8/20us impulse rating:

  • Capacitance: line to line <40pF

  • line to frame <40pF

  • Connection: 8 way RJ45 socket on 2HU 19" rack panel.

  • Dimensions: 19" rack mount x 2HU

Options

  • Cat No. Application

  • RJ45-8CAT5 8 port RJ45 protector

  • RJ45-16CAT5 16 port RJ45 protector

 

Novaris Technologies Pty Ltd  ACN  065 427 232    72 Browns Road, Kingston, TAS. 7050  TEL:  036229 7233  AUSTRALIA 

FAX: 03 6229 2748. Copyright  Ó1996 Novaris Technologies Pty Ltd. International FAX: +613 6229 2748

 